Specifications
Detection Range .............. 0.229 m to 4.064 m (9 inches to 12.4 feet)
Input Voltage .................... 10-30 VDC
Inputs............................... RS-232 and (4) discrete
Outputs ............................ (4) solid state relays (130 mA max) and RS-232.
Accuracy ......................... 0.25% of range
Adjustments .................... RS-232
Total Current Draw: .......... TBA
Transducer Type: ............. Electrostatic
Operating Temperature:.... -30 to 70°C
Sample Rate: ..................... Programmable 4 to 12 Hz
Beam Pattern: ................... off axis
6.70"
8.00"
2.94"
7.00"
1.75"
6.00"
0.25"
1.825"
1.70"
3.375"
3.00"
0.1875"
Dimensions
Controller ......................... 6.7 in. H x 6 in. W x 2.95 in. D
Transducer Assembly...... 3 in. H x 1.825 in. W x 1.7 in. D
(Both housings are aluminum)