Apg MNU Slave Sensor user manual Manual de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
MNU Series Ultrasonic Sensors Rev. B1, 5/13
24
Automa! on Products Group, Inc.
APG...Providing tailored solu• ons for measurement applica• ons
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]om
Applica! on Type 7: Pounds
Allows the user to apply a conversion mul! plier to the calculated level reading.
(measurement result in register 30303-30304)
NOTE: the decimal place for the Mul! plier is always assumed to be in the
thousands posi! on, therefore a se" ng of 206250 = 206.250 actual mul! plier.
Example: suppose the product in a tank weighs 206.25 pounds for every
inch of level. Assuming the Units are set to inches (Units = 2), the Mul! plier
would be 206250.
Register Func! on Value Range
40401 Units 1 to 3
40402 Applica! on Type 7
40404 Decimal Place 0 to 3
40405 Max Distance ≥ Empty Distance
40406 Full Distance Typically = Blanking Distance
40407 Empty Distance 0 to 10364 mm
40436-40437 Mul! plier 0 to 1000000 (1000 = 1.000)
Vista de pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 39 40

Comentarios a estos manuales

Sin comentarios